Calculation of the removal of iron from groundwater in a fast filter

Authors

  • V.L. Polyakov Institute of Hydromechanics of the NAS of Ukraine, Kiev
  • S.Yu. Martynov National University of Water and Environmental Engineering, Rivne

DOI:

https://doi.org/10.15407/dopovidi2019.03.035

Keywords:

clarification, concentration, deposition, hydroxide, iron, oxidation, rigorous solution, transfer

Abstract

The nonlinear problem of transfer and deposition of ferric iron in the bed layer of a fast filter is posed with regard for the oxidation of ferrous iron and is strictly solved. We have constructed relations and equations for the
calculation of an increase in the head loss in the bed, as well as changes in the concentrations of suspended and deposited particles of Fe hydroxide in time and along the bed height. By examples, we forecast a growth in the content of Fe hydroxide in the filtrate and deposited form. The possibility of a reliable substantiation of technological and constructional parameters on the basis of the obtained solution is discussed.

Downloads

Download data is not yet available.

References

Alan, C., Twort, Don, D., Ratnayaka & Malcolm, J., Brandt. (2006). Water Supply. Fifth Edition. London: IWA Publishing.

Sharma, S. K. (2009). Adsorptive Iron Removal from Groundwater: Dissertation for Degree of Doctor. Delft, The Netherlands.

Orlov, V. & Martynov, S. (2015). Contact deferrization water on polystyrene filters. Saarbr cken, Deutschland: LAP LAMBERT, Acad. Publ. (in Russian).

Lavanya, R.S ., Ulavi, S., Lokesh, K. S. & Tech Scholar, M. (2014). Water softening and deironing of ground water using sulfonated polystyrene beads. Int. journal of engineering research & technology, 3, pp. 2124-2127.

Water Treatment Handbook (2007). 7th Edition. 2 Vols. Paris: Lavoisier.

Tugay, A. M., Oliynuk, O. Ya. & Tugay, Ya. A. (2004). Productivity of water intake well under clogging conditions. Kharkiv: KHAMG (in Ukrainian).

Rakic, V., Damjanovic, L., Rac, V., Stasic, D., Dondur, V. & Auroux, A. (2010). The adsorption of nicotine from aqueous solutions on different zeolite structures. Water Res., 44, pp. 2047-2057. doi: https://doi.org/10.1016/j.watres.2009.12.019

Polyakov, V. L., Martynov, S. Yu. (2017). Mathematical modeling of the dynamics of the accumulation of iron compounds in the input cross section of the filter loading. Problems of Water Supply, sewerage and Hydraulics, 28, pp. 272-280 (in Ukrainian).

Polyakov, V. L., Martynov, S. Yu. & Avtayeva, O. V. (2018). Mathematical modeling of adsorption con ta mina tion in the loading of deironing filters. Bulletin of NUWEE. No. 1(81), pp. 75-86 (in Ukrainian).

Stankyavichus, V. I. (1978). Water deironing by filtration (fundamentals of the theory and the calculation of installations). Vilnius: Moxlas (in Russian).

Polyakov, V. L. (2018). About modeling of the removal of dissolved iron by filtration from groundwater. Dopov. Nac. acad. nauk Ukr., No. 12, pp. 37-45 (in Russian). doi: https://doi.org/10.15407/dopovidi2018.12.037

Kiselev, S. K. & Oleynik, A. Ya. (1998). Modeling iron removal from water by filtration under changes in filtration properties. Dopov. Nac. acad. nauk Ukr., No. 7, pp. 183-187 (in Russian).

Published

21.04.2024

How to Cite

Polyakov, V., & Martynov, S. (2024). Calculation of the removal of iron from groundwater in a fast filter . Reports of the National Academy of Sciences of Ukraine, (3), 35–45. https://doi.org/10.15407/dopovidi2019.03.035

Most read articles by the same author(s)