State and Perspectives of the Center for Collective Use «Accelerated Mass Spectrometry» of the Institute of Applied Physics
DOI:
https://doi.org/10.15407/scin10.02.008Keywords:
accelerated mass spectrometry, center for collective use, carbon isotope 14C, archeology, radiochemistry.Abstract
The paper discusses the development of the Center for collective use device «Accelerated Mass Spectrometry» IAP NASU. The results of the first experiments on the dating of some archaeological samples is presented. The main tasks aimed at further development of the Center are given.
References
Libby, W.F., Anderson, E.C., and Arnold,J.R.: Age Determination by Radiocarbon Content.World-Wide Assay of Natural RadiocarbonScience,109, 2827, 227-228 (1949).
Kutschera, W.: Progress in Isotope Analysis at Ultra-Trace Level by AMS. International Journal of Mass Spectrometry, 242, 145-160 (2005).
https://doi.org/10.1016/j.ijms.2004.10.029
Kutschera, W.: Applications of Accelerator Mass Spectrometry.Intern. J. of Mass Spectrometry, 349-350, 203-218 (2013).
https://doi.org/10.1016/j.ijms.2013.05.023
Blinov, A.V.: Accelerator Mass Spectrometryof Cosmogenic Nuclides. The Soros Educational Journal, 8, 71-75 (1999) (in Russian).
Laeter, J.R.: Mass spectrometry and Geochronology.Mass Spectrometry Reviews, 17, 2, 97-125 (1988).
https://doi.org/10.1002/(SICI)1098-2787(1998)17:2<97::AID-MAS2>3.0.CO;2-J
Sukhodub, L.F.: Application of Accelerator Mass Spectrometry to Environmental, Medical, and Biological Studies. Science and Innovation, 6, 17—36 (2010) (in Russian).
Kuzmin, Y.V.: Radiocarbon and Old World Archaeology: Shaping a Chronological Framework. Radiocarbon, 51, 1, 149-172 (2009).
Chamizo, E., Lopez-Gutierrez, J.M., Ruiz-Gomez, A. et al.: Status of the Compact 1 MV AMS facility at the Centro Nacional de Aceleradores (Spain).Nuclear Instruments and Methods in Physics ResearchB, 266, 2217-2220 (2008).
https://doi.org/10.1016/j.nimb.2008.02.061
Chamizo, E., Enamorado, S.M., Garcia-Leon, M. et al.: Plutonium Measurements on the 1 MV AMS System at the Centro Nacional de Aceleradores (CNA).Nuclear Instruments and Methods in Physics Research B, 266, 4948-4954 (2008).
https://doi.org/10.1016/j.nimb.2008.08.001
OECD Series on Principles of Good Laboratory Practice and Compliance Monitoring. No. 1.OECD Principles on Good Laboratory Practice, ENV/MC/CHEM(98)17, OECD: Paris, (1997).
The Regulations for Labor Protection during the Operational Period of Chemical Laboratories. Order of the Ministry for Emergency Response of Ukraine of 11.09.2012, no. 1192 http://zakon2.rada.gov.ua/laws/show/z1648-12 (in Ukrainian).
Fahrni, S.M., Wacker, L., Synal, H.-A., and Szidat, S.: Improving a Gas Ion Source for 14C AMS.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 294, 320-327 (2013).
https://doi.org/10.1016/j.nimb.2012.03.037
Ruff, M., Szidat, S., Gaggeler, H.W. M. et al.: Gaseous Radiocarbon Measurements of Small Samples.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 268, 7-8, 790-794 (2010).
https://doi.org/10.1016/j.nimb.2009.10.032
Fahrni, S.M., Gaggeler, H.W., Hajdas, I. et al.: Direct Measurements of Small 14C Samples After Oxidation in Quartz Tubes.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 268, 7-8, 787-789 (2010).
https://doi.org/10.1016/j.nimb.2009.10.031
Wacker, L., Munsterer, C., Hattendorf, B. et al.: Direct Coupling of a Laser Ablation Cell to an AMS.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 294, 287-290 (2013).
https://doi.org/10.1016/j.nimb.2012.02.013
Wacker, L., Fahrni, S.M., Hajdas, I. et al.: A Versatile Gas Interface for Routine Radiocarbon Analysis with a Gas Ion Source.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 294, 315-319 (2013).
https://doi.org/10.1016/j.nimb.2012.02.009
Sheng, Xua, Dougans, A., Freeman Stewart, P.H.T. et al.: A Gas Ion Source for Radiocarbon Measurement at SUERC.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 259, 1, 76-82 (2007).
https://doi.org/10.1016/j.nimb.2007.01.311
Von Reden, K.F., Roberts, M.L., Jenkins, W.J. et al.: Software Development for Continuous-Gas-Flow AMS.Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 266, 10, 2233-2237 (2008).
https://doi.org/10.1016/j.nimb.2008.03.001
Thomas, A.T., Stewart, B.J., Ognibene, T. et al.: Directly Coupled HPLC-AMS Measurement of Chemically-Modified Protein and Peptides.Anal. Chem., 85, 7, 3644-3650 (2013).